GigaBeam_Gi-Core_WiFiber_G1.25

User can be logged in by serial, telnet and ssh to a CLI or to shell. Depends on setting in /etc/passwd.

User with leve 1 logged to CLI can access and change all settings according to manual

g1.25_installation_and_operations_manual_031706.pdf

Basic setting overview:
1 Login to the radio using CLI as an admin user (level 1).

Change ip address
 2 GVFR#c t
 3 GVFR(config)#conf
 4 GVFR(config-Conf)#ethernet
 5 GVFR(config-Conf-Ethernet)#set ipaddress 192.168.1.230 (default)
 6 GVFR(config-Conf-Ethernet)#set addressmask 255.255.255.0
 7 GVFR(config-Conf-Ethernet)#set gateway 192.168.1.1

Set admin password
 2 GVFR#c t
 3 GVFR(config)#conf
 4 GVFR(config-Conf)#async
 5 GVFR(config-Conf-async)#Admin
 6 GVFR(config-Conf-async-admin)#set password
 The screen displays prompt for a new password
 success {new password}

To save the configuration to flash, continue with the following commands:
 2 GVFR#c t
 3 GVFR(config)#conf
 4 GVFR(config-Conf)#misc
 5 GVFR(config-Conf-Misc)#set save on

Check signal

configure terminal
rad
atpc
get rxsignal

Check data link on sfp TBD

Get rx signal

 snmpwalk -Os -Cc -c public -v 1 10.33.8.2 enterprises.22113.2.11.4
 enterprises.22113.2.11.4.0 = STRING: "-40.200    `"

Get tx signal

 snmpwalk -Os -Cc -c public -v 1 10.33.78.210 enterprises.22113.2.11.2 -On
 .1.3.6.1.4.1.22113.2.11.2.0 = STRING: "0.0313"
 

Reboot spoje

WiFiber# c t

WiFiber(config)# conf

WiFiber(config-Conf)# asy

WiFiber(config-Conf-Async)# misc

WiFiber(config-Conf-Async-Misc)# reboot
Are you sure?(y/n):

Zprovoznění zasněženého spoje

Arista switche v případě packetloosu zakážou daný port
je treba dat shutdown a pak "no shutdown" tim se odcaruje ze stavu errdisabled